Temperature & Humidity Sensor
Features
High measurement accuracy
±0.5℃ temperature accuracy and ±3%RH humidity accuracy at 25℃ for reliable readings.
Integrated temperature & humidity sensing
A single wall-mounted probe measures both temperature and humidity.
Industrial-grade microprocessor
Built-in high-performance microprocessor with advanced digital-to-analog conversion for exceptional reliability.
Multiple probes available
A variety of probes are available to suit different installation needs.
Flexible analog & digital output
4~20mA / 0~5VDC / 0~10VDC analog outputs plus RS485 Modbus output.
Excellent long-term stability
Drift of ≤0.1℃/year for temperature and ≤0.1%RH/year for humidity.
Wide application range
Ideal for building automation, HVAC, climate control, greenhouses, and the pharmaceutical and chemical industries.
The SEN101-2001 temperature and humidity sensor features a wall-mounted installation and utilizes premium digital sensor components. With an industrial-grade microprocessor and advanced digital-to-analog conversion, this sensor ensures exceptional reliability, high precision, and excellent interchangeability.It is widely applicable in building automation, climate control, HVAC signal acquisition, greenhouses, and the pharmaceutical and chemical industries.
- High measurement accuracy
- Built-in high-performance microprocessor
- A variety of probes are available
- Integrated use of temperature and humidity Superior performance, good long-term stability

Specifications
Models
Measurement
| Probe temperature | -40~+80℃ |
|---|---|
| Probe humidity | Relative humidity 0%~100%RH |
| Temperature accuracy | ±0.5℃ (25℃) |
| Humidity accuracy | ±3%RH (5%RH~95%RH, 25℃) |
| Temperature long-term stability | ≤0.1℃/year |
| Humidity long-term stability | ≤0.1%RH/year |
| Temperature response time | ≤18/sec (1m/s wind speed) |
| Humidity response time | ≤6 seconds (1m/s wind speed) |
Output
| Signal output | 4~20mA / 0~5VDC / 0~10VDC, RS485 output (Modbus protocol) |
|---|---|
| Device address | 1~255 can be set, default is 1 |
| Device baud rate | 4800, 9600, 19200, 38400, 57600, 115200 optional, default 9600 |
| Byte format | 8 data bits, 1 stop bit, no parity |
Electrical
| Operating voltage | 10~30VDC (Note: 0~10VDC output limited to 24VDC power supply) |
|---|---|
| Maximum power consumption | Analog signal (voltage/current) 1.2W MAX.; Digital signal ≤0.4W |
| Electrical connections | Direct out |
Environment
| Sensor body working temperature | -40~80℃, 0%RH~100%RH |
|---|