Solar Output Fell 8% and Nobody Cleaned the Radiometer: Soiling Losses and Cleaning Schedules
Share
- A dirty radiometer under-reads irradiance, so the performance ratio looks fine while the plant is actually losing energy.
- Dust scatters light, pollen and organic deposits absorb it, and a single bird dropping can shade a meaningful share of a small sensor.
- Soiling is worst at low sun angles, so a dirty radiometer can read almost normally at noon and badly wrong in the morning and evening.
- Clean the dome with clean water and a soft cloth, never wipe a dry dusty dome, and never use abrasives that scratch the glass.
- Log the reading before and after every cleaning on a clear day, and keep a clean reference radiometer to compare against.
Table of contents
The monthly generation report was 8% short, and nobody could say why.
The solar farm had been running for eighteen months when the operations manager noticed the gap. The array's monthly energy output was 8% below what the monitoring software had predicted, and the shortfall had been growing quietly for weeks. The panels were inspected first: no cracked modules, no failed strings, no inverter alarms. The inverters were tested next and passed. The performance ratio — the number the team used to judge the health of the whole plant — still looked acceptable, which made the missing energy even harder to explain. It was only when a technician climbed to the weather station to check the reference radiometer that the cause became obvious: the glass dome of the instrument was filmed with dust, pollen and a streak of dried bird droppings. The sensor that the whole performance calculation depended on had been slowly going blind, and it had hidden the loss from the very dashboard meant to catch it.
A radiometer is the plant's eyes for sunlight. It measures solar irradiance — the power of sunlight arriving at a surface, in watts per square metre — and every yield forecast, performance ratio and soiling estimate is built on that one number. When the instrument itself gets dirty, the error does not show up as a warning; it shows up as a quiet, systematic under-reading that makes the plant look healthier than it is while real generation slips away. This article explains how soiling corrupts an irradiance measurement, how to tell a dirty sensor from a failing one, and how to set a cleaning schedule that keeps the reference measurement honest.
How a radiometer measures sunlight, and how dirt gets in the way
Most field radiometers work in one of two ways. A thermopile radiometer absorbs sunlight on a blackened surface and measures the tiny temperature difference between that surface and the instrument body; the voltage it produces is proportional to the irradiance. A photodiode radiometer uses a silicon sensor whose current rises with the light falling on it. Either way, the measurement starts with light reaching a sensitive surface through a glass dome or diffuser, and anything that sits on that surface changes the result before the electronics ever see it.
Soiling works on that first step. A film of dust scatters incoming light, so some of it never reaches the sensor. Pollen and organic deposits absorb light, particularly in the blue end of the spectrum that a photodiode is most sensitive to. Bird droppings are worse: a single opaque spot can shade a meaningful fraction of a small sensor. The result is always in the same direction — the instrument reads low — but the size of the error depends on what is on the glass, how thick it is, and the angle of the sun. Soiling is worst at low sun angles, when light crosses the dirty film at a slant and a larger share is scattered, which is one reason a dirty radiometer can read almost normally at noon and badly wrong in the morning and evening.
The cruel part is what a dirty reference does to the plant's own numbers. The performance ratio compares actual energy output with the output the measured irradiance says the array should have produced. If the radiometer under-reads by 8%, the expected output is calculated 8% low, and the ratio comes out looking fine — the plant appears healthy while both the panels and the reference are losing the same light to the same dirt. Soiling of the reference sensor does not just add error; it cancels the alarm that would have caught the panels' own soiling. A site can run for months in that blind spot, losing energy on both sides of the equation, until someone compares the numbers with a neighbouring plant or a satellite estimate and finds the gap.
Panels and radiometers sit in the same dust, but they do not soil at the same rate: the radiometer's small dome collects a different mix of deposits, its tilt is usually different, and it has no self-cleaning from rain run-off in the same way a large tilted panel does. The reference sensor has to be cleaned on its own schedule, not as an afterthought to panel washing.
Selection criteria: choosing a radiometer that stays honest
Judge a radiometer for a solar site by how its reading behaves when it is not perfectly clean, and by how easy it is to keep clean. First, look at the optical design: a thermopile instrument with a glass dome responds across the full solar spectrum, which matches the panels' own response more closely than a silicon photodiode, whose spectral response is narrower and which can be thrown off more by the selective absorption of organic deposits. Second, consider the dome: a larger dome with a smooth, hard surface is easier to wipe without scratching than a small or textured one, and a dome that can be cleaned without dismantling the instrument will actually get cleaned. Third, think about the mounting: the instrument should sit where a technician can reach it safely for cleaning without shutting the plant down, and where its tilt can be set to match the array or the horizontal as the measurement requires — plane-of-array data and horizontal data answer different questions, and a sensor tilted the wrong way answers neither.
Be honest about what a radiometer cannot do. It cannot tell you how dirty the panels are; it can only tell you how much light is arriving, and that number is only true if the instrument itself is clean. A single radiometer cannot distinguish a soiled sensor from a genuinely hazy day — that takes a second, clean reference, or a comparison against a satellite or nearby station. And no radiometer, however good, compensates for a cleaning schedule that nobody follows: the instrument is only as honest as its last cleaning.
Installation pitfalls that make soiling worse
Mounting the radiometer where it cannot be reached. An instrument bolted to the top of a tall mast or on the far side of an array is a sensor that will not be cleaned. Put it where a technician can reach the dome from a ladder or a walkway, and where cleaning it does not mean stepping on modules.
Tilting it flat when the array is tilted. A horizontal radiometer and a tilted array soil differently and measure different light. If the performance calculation needs plane-of-array irradiance, the reference must be tilted to the same angle as the array, levelled properly, and checked after any work on the mounting.
Letting the dome sit in the drip line of a structure. A radiometer mounted under a panel edge, a cable tray or a roof overhang collects concentrated drips and the dirt they carry. Keep the dome clear of anything that drips onto it, and check the mounting after storms for shifted brackets.
Running the cable where cleaning water can reach the connector. Cleaning involves water near the instrument. A cable gland that points upward, or a connector that sits in a puddle on the mounting plate, will let water in over time. Route the cable down from the instrument with a drip loop below the gland, and keep the connector dry.
Cleaning with the wrong materials. Abrasive cloths, dry wiping on a dusty dome, and harsh solvents scratch or haze the glass, and a scratched dome scatters light permanently — the instrument reads low forever, no matter how often it is cleaned after that. Use clean water and a soft cloth, and never wipe a dry, dusty dome.
Verification: proving the reading is true
The most convincing check is a clean-reference comparison. Keep a second radiometer of the same type, cleaned on a strict schedule, and compare the two over a clear day. If the working instrument reads a few percent below the clean one and the gap closes after cleaning, the problem was soiling, not the sensor. A simpler routine is the cleaning test: record the reading, clean the dome carefully, and record again under the same sky within minutes. On a stable, clear day the jump after cleaning is a direct measure of the soiling loss, and logging that number each time builds a picture of how fast the site soils.
Set the cleaning interval from the site, not from a calendar. A desert site near a dirt road may need weekly cleaning; a coastal site may need cleaning after every dry, windy spell; a site surrounded by farmland may need extra attention during harvest and pollen season. Check the dome after rain, and do not assume it is clean.
Troubleshooting
| Symptom | Likely cause | How to check |
|---|---|---|
| Irradiance reads low, and jumps up after cleaning | Soiling on the dome — dust, pollen or bird droppings scattering light | Log the before-and-after cleaning readings on a clear day; repeat to find the site's soiling rate |
| Readings drift down over weeks, but cleaning only partly restores them | A scratched or hazed dome, or deposits baked onto the glass | Inspect the dome in raking light for scratches or a permanent film; compare against a clean reference sensor |
| Performance ratio looks fine while generation falls short | The reference radiometer is soiled, so expected output is calculated too low | Clean the radiometer and recalculate the performance ratio; compare with a neighbouring station or satellite estimate |
| Readings look normal at noon but wrong in the morning and evening | Soiling film scattering light more at low sun angles | Compare the morning and evening readings against a clean reference; clean and re-check |
| Output drops after light rain instead of recovering | Rain left a mineral film on the dome, or washed dirt onto it from above | Inspect the dome after rain and clean with distilled water; check for a drip source above the instrument |
| Reading changes suddenly after maintenance on the mast | Mounting knocked out of level or tilt during the work | Re-level and re-check the tilt, then compare against the clean reference |
Checklist: keeping the radiometer honest
- Mount the radiometer where a technician can reach the dome safely for cleaning.
- Set the tilt to match the measurement you need — plane-of-array or horizontal — and level it properly.
- Clean the dome with clean water and a soft cloth; never wipe a dry, dusty dome and never use abrasives.
- Log the reading before and after every cleaning, on a clear day, to track the site's soiling rate.
- Set the cleaning interval from the site's dust, pollen and bird activity, not from a fixed calendar.
- Keep a clean reference radiometer for comparison, and investigate any gap between the two.
- Check the dome after rain — light rain often leaves a film rather than cleaning it.
- Re-check level and tilt after any work near the mounting.
- Route the cable with a drip loop below the gland and keep the connector dry during cleaning.
- Recalculate the performance ratio after cleaning the radiometer, and compare it with the pre-cleaning figure.
The missing 8% was never a mystery in the end — it was the reference sensor going dirty at the same rate as the panels, and the performance ratio quietly forgiving the loss. A radiometer is only a reference while it is clean, and keeping it clean is a small, regular job that protects every number built on it. Clean it on a schedule the site dictates, log the before-and-after readings, and keep a clean reference to compare against, and the instrument will tell the truth about the light — including the days when the truth is that the panels need washing too. For a field radiometer built for this kind of plant-side duty, with both 4-20 mA and RS485 output so the reading can feed a logger or a SCADA system directly, the optical irradiance radiometer solar radiation sensor is the instrument this article's cleaning routine is written around.
Our engineers can help you pick the right model, check compatibility, and get your installation right the first time.
Optical Irradiance Radiometer Solar Radiation Sensor (4-20mA & RS485)View product →
Related Blogs
The Greenhouse Climate Loop: From Sensors to Vents, Fans and Heaters
Adding a Camera to a Sensor Site: What the Picture Adds That Numbers Can't
The Light Sensor Housing Corroded in One Season by the Sea: Salt Spray and Corrosion